| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | UserConfiguration | Type | NumberofPositions | Voltage-Input | Power(Watts) | Voltage-Isolation | Efficiency | Features | OperatingTemperature | Size/Dimension | Height | ApprovalAgency | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|   | XLC-01CONFIG POWER CHASSIS 600W 4 SLOT | 3,020 | 249.83 | RFQ |   Datasheet | Bulk | Xgen, XL | Active | - | Standard | 4 | 85 ~ 264 VAC | 600 W | 3 kV | 89% | Fan Fail, Temperature Alarm | -20°C ~ 70°C | 10.24 L x 3.50 W (260.0mm x 89.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | CX06S-0000-N-ACONFIG POWER CHASSIS 600W 4 SLOT | 116 | 270.27 | RFQ |   Datasheet | Box | CoolX™600 NFF | Active | - | Standard, Ultra Quiet | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 93% | - | -40°C ~ 70°C (With Derating) | 8.50 L x 4.50 W (215.9mm x 114.3mm) | 1.54 (39.1mm) | CE, cTUVus | 
|   | CX06M-0000-N5BCONFIG POWER CHASSIS 600W 6 SLOT | 3,338 | 338.74 | RFQ |   Datasheet | Bulk | CoolX™600 NFF | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 94% | - | -40°C ~ 85°C (With Derating) | 8.50 L x 4.50 W (215.9mm x 114.3mm) | 1.50 (38.1mm) | CE | 
|   | XCE-00CONFIG PWR CHASSIS 1340W 6 SLOT | 2,740 | 451.65 | RFQ |   Datasheet | Box | Xgen, XC | Active | - | Standard | 6 | 85 ~ 264 VAC | 1340 W | 3 kV | 90% | - | -20°C ~ 70°C | 10.55 L x 5.00 W (268.0mm x 127.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | XVE-04CONFIGURABLE POWER SUPPLY | 2,562 | 532.90 | RFQ |   Datasheet | Box | Xgen, XV | Active | - | Medical | 6 | 85 ~ 264 VAC | 1340 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.55 L x 5.00 W (268.0mm x 127.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | XWB-04CONFIGURABLE POWER SUPPLY | 3,338 | 527.74 | RFQ |   Datasheet | Box | Xgen, XW | Active | - | Medical, Ultra Quiet | 6 | 85 ~ 264 VAC | 600 W | 4 kV | 90% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.24 L x 5.00 W (260.0mm x 127.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | XCC-00CONFIG PWR CHASSIS 1000W 6 SLOT | 2,921 | 377.39 | RFQ |   Datasheet | Bulk | Xgen, XC | Active | - | Standard | 6 | 85 ~ 264 VAC | 1000 W | 3 kV | 90% | - | -20°C ~ 70°C | 10.24 L x 5.00 W (260.0mm x 127.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | XCD-00CONFIG PWR CHASSIS 1200W 6 SLOT | 3,351 | 418.97 | RFQ |   Datasheet | Bulk | Xgen, XC | Active | - | Standard | 6 | 85 ~ 264 VAC | 1200 W | 3 kV | 90% | - | -20°C ~ 70°C | 10.24 L x 5.00 W (260.0mm x 127.0mm) | 1.59 (40.40mm) | CE, cURus | 
|  | XFCS01CONFIG PWR CHASSIS 1000W 6 SLOT | 3,048 | 740.09 | RFQ |   Datasheet | Bulk | Xgen, XF | Active | - | High Reliability, COTS | 6 | 85 ~ 264 VAC | 1000 W | 3 kV | 89% | Fan Fail, Ruggedized, Temperature Alarm | -55°C ~ 70°C (With Derating) | 10.55 L x 5.00 W (268.0mm x 127.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | XLA-01CONFIG POWER CHASSIS 200W 4 SLOT | 2,559 | 239.24 | RFQ |   Datasheet | Bulk | Xgen, XL | Active | - | Standard | 4 | 85 ~ 264 VAC | 200 W | 3 kV | 89% | Fan Fail, Temperature Alarm | -20°C ~ 70°C | 10.24 L x 3.50 W (260.0mm x 89.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | UX4CCONFIG POWER CHASSIS 600W 4 SLOT | 2,717 | 267.84 | RFQ |   Datasheet | Box | UltiMod, UX | Active | - | Medical | 4 | 85 ~ 264 VAC | 600 W | 4 kV | 90% | Conformal Coating | -40°C ~ 70°C (With Derating) | 10.24 L x 3.50 W (260.0mm x 89.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | XCC-01CONFIG PWR CHASSIS 1000W 6 SLOT | 2,588 | 377.39 | RFQ |   Datasheet | Bulk | Xgen, XC | Active | - | Standard | 6 | 85 ~ 264 VAC | 1000 W | 3 kV | 90% | Fan Fail, Temperature Alarm | -20°C ~ 70°C | 10.24 L x 5.00 W (260.0mm x 127.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | CX10S-000000-N-ACONFIG POWER CHASSIS 1000W 6 SLO | 2,275 | 414.41 | RFQ |   Datasheet | Bulk | COOLX®1000 | Active | - | Medical | 6 | 85 ~ 264 VAC | 1000 W | 4 kV | 93% | - | -40°C ~ 85°C (With Derating) | 10.00 L x 6.50 W (254.0mm x 165.1mm) | 1.00 (25.4mm) | CSA, EN, IEC, UL | 
|   | CX18S-000000-N1ACONFIG POWER CHASSIS 1800W 6 SLO | 3,213 | 432.43 | RFQ |   Datasheet | Bulk | CoolX™1800 | Active | - | Standard | 6 | 85 ~ 264 VAC | 1800 W | 4 kV | 91% | - | -40°C ~ 70°C (With Derating) | 10.31 L x 5.00 W (262.0mm x 127.0mm) | 1.60 (40.6mm) | CE | 
|   | XQC-00CONFIG PWR CHASSIS 1200W 6 SLOT | 3,305 | 455.23 | RFQ |   Datasheet | Box | Xgen, XQ | Active | - | Standard, Low Noise | 6 | 85 ~ 264 VAC | 1200 W | 3 kV | 90% | - | -20°C ~ 70°C | 10.24 L x 5.00 W (260.0mm x 127.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | XCEC01CONFIG PWR CHASSIS 1340W 6 SLOT | 3,222 | 469.12 | RFQ |   Datasheet | Bulk | Xgen, XC | Active | - | Standard | 6 | 85 ~ 264 VAC | 1340 W | 3 kV | 90% | Conformal Coating, Fan Fail, Temperature Alarm | -20°C ~ 70°C | 10.55 L x 5.00 W (268.0mm x 127.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | CX18M-000000-N-ACONFIG DC PWR MOD 1800W FAN COOL | 3,531 | 480.48 | RFQ |   Datasheet | Bulk | CoolX™1800 | Active | - | Medical | 6 | 85 ~ 264 VAC, 120 ~ 300 VDC | 1800 W | 4 kV | 91% | Remote Sense | -40°C ~ 70°C (With Derating) | - | - | CE, cTUVus | 
|   | CX18M-000000-N5BCONFIG POWER CHASSIS 1800W 6 SLO | 3,162 | 494.46 | RFQ |   Datasheet | Bulk | CoolX™1800 | Active | - | Medical | 6 | 85 ~ 264 VAC | 1800 W | 4 kV | 91% | - | -40°C ~ 70°C (With Derating) | 10.31 L x 5.00 W (262.0mm x 127.0mm) | 1.60 (40.6mm) | CE | 
|   | XLA-00CONFIG POWER CHASSIS 200W 4 SLOT | 2,897 | 239.24 | RFQ |   Datasheet | Bulk | Xgen, XL | Active | - | Standard | 4 | 85 ~ 264 VAC | 200 W | 3 kV | 89% | - | -20°C ~ 70°C | 10.24 L x 3.50 W (260.0mm x 89.0mm) | 1.59 (40.40mm) | CE, cURus | 
|   | XLC-D0CONFIGURABLE POWER SUPPLY | 3,094 | 257.38 | RFQ |   Datasheet | Box | Xgen, XL | Active | - | Standard, Low Noise | 4 | 85 ~ 264 VAC | 600 W | 3 kV | 89% | Fan Fail, Temperature Alarm | -20°C ~ 70°C (With Derating) | 10.24 L x 3.50 W (260.0mm x 89.0mm) | 1.59 (40.40mm) | CE, cURus |